Address your needs quickly by calling 800-926-1926 or 262-692-2416

126 Series Multi-Flex™ Rigid Core Inflatable By-Pass Plugs Sizes: 1 1/2" to 12"

For other inflatable plugs click here

By-Pass (Flow-Thru) Design Allows Continuous Flow

Rigid By-Pass Plugs are generally made for higher pressure applications.

They can be manufactured to meet a customer's exact requirements.

These plugs are generally built on a hollow P.V.C. or aluminum core and have a 1/8" to 3/8" F npt inflation port.

 

Rigid Core Rubber Inflatable By-Pass Plugs
Custom Rigid Core Rubber Inflatable By-Pass Plugs

Click an Item Number below for the Web Store

Rigid By-Pass Plugs
Pipe Diameter
Maximum
**Pipeline

By-Pass
Connection

in npt

Deflated
Length
Shpg
Wt
lbs
Item
Number
Unit
Price
Each
Maximum Minimum
Inflation
Max. Head
in mm in mm psig bar ft m in m
2 51 1.60 40 75 5.0 57 17.5 1/8 F 8 0.2 1 126-002-8 US $248.00
3 76 2.00 51 75 5.0 57 17.5 1/4 F 10 0.3 1 126-003-8 US $266.00
4 102 3.50 88 75 5.0 57 17.5 1/2 F 12 0.3 2 126-004-8 US $282.00
7 178 5.75 152 85 5.7 41 12.6 2 F 14 0.3 5 126-006-8 US $470.00
8 203 7.00 178 85 5.7 41 12.6 3 F 16 0.4 10 126-008-8 US $616.00
10 254 9.00 229 85 5.7 41 12.6 3 F 18 0.4 11 126-010-8 US $692.00
12 305 11.00 279 85 5.7 41 12.6 3 F 22 0.5 12 126-012-8 US $902.00

Other sizes available upon request.

**Inflatable Plug Warning: Maximum head pressures that a pipe plug may restrain can only be estimated. Slippage is influenced by many factors including fluid in the pipe, coefficient of pipeline friction, pressure required to inflate the plug, and accuracy of pressure gauges. Generally, a Multi-Flex™ Inflatable Plug inserted fully into pipeline will begin slipping between 50% and 80% of the inflation pressure if it has an inflated pipe contact length of 1 ½ to 2 times the diameter, but even a head of 50% of the inflation pressure may cause slippage with some liquids. The inflation pressure is also subject to temperature change and debris or protrusions in the pipeline that could rupture the plug. The inflation pressure should be monitored and plugs anchored and/or mechanically blocked when slippage may cause property damage or injury.  NEVER use a test pressure greater than the capacity of the weakest pipe or component in the system. NEVER use an inflatable plug when its failure would cause injury.

Custom configurations also available

Price subject to change without notice

Petersen Terms & Conditions Apply

Products covered by one or more of the following patents: 4,565,222; 5,353,842; 5,901,752; 6,446,669; 6,568,429; 6,899,138 and other applications pending.