Address your needs quickly by calling 800-926-1926 or 262-692-2416

116 Series Multi-Flex™ Lateral Joint "T" Packers Sizes: 4" to 24"

For other inflatable plugs click here

Inflation controllers, gauges, hoses, etc. on our accessories page

Deflates To Small Flexible Size For Easy Insertion

Smooth, Even Relining

The Petersen® Packer has a fixed inflated diameter independent of the pipeline. This allows for a smooth repair with a constant diameter unlike rubber packers that generally follow the contour of the broken area of the pipeline causing an irregular I.D. repair.

Easy Installation and Removal

Small deflated diameter, light weight and flexibility allow installation of long Multi-FlexT Packers through a small opening. Removal after deflating is just as easy.

Flow-Thru

The by-pass design allows main line flow through the Multi-FlexT Packer during repairs.

Light Weight

Petersen® Multi-FlexT Packers are much lighter than molded rubber packers for easy placement.

High Strength Flexible Materials

Inflatable Multi-FlexT Packers are made from very high strength flexible woven and non-woven materials.  Connections are available for air, hot water, steam inflation and recirculation.

Air, Hot Water or Steam

Packers can be fitted with connections or use with circulating hot water, steam or ambient cure with air or water.

Custom Confirurations

Custom Flexible and Rigid Plugs and Packers are manufactured for many high temperature and severe chemical applications. Please contact a Petersen engineer to discuss your requirements.

Click an Item Number below for the Web Store

90° Lateral
Main Line Lateral Line

Maximum

Inflation

Pipeline

Max. Head*

Inflation

Port

(QC)

Shpg
Wt
lbs
Item
Number
Unit
Price
Each

Maximum

Diameter

Contact

Length

Maximum

Diameter

Contact

Length

in mm in mm in mm in mm psig bar ft m
4 102 16 406 2 51 16 406 25 1.7 28 8.8 1/4" 6 116-0402-901616 US $1,240.00
6 152 18 457 4 102 24 610 25 1.7 28 8.8 1/4" 8 116-0604-901824 US $1,440.00
8 203 24 610 4 102 32 812 25 1.7 28 8.8 1/4" 10 116-0804-902432 US $1,880.00
10 254 40 1016 4 102 40 1016 25 1.7 28 8.8 1/4" 12 116-1004-904040 US $2,250.00
12 305 48 1219 6 152 48 1219 25 1.7 28 8.8 1/4" 14 116-1206-904848 US $2,630.00
18 457 48 1219 6 152 48 1219 25 1.7 28 8.8 1/4" 18 116-1806-904848 US $3,210.00
24 610 48 1219 6 152 48 1219 25 1.7 28 8.8 1/4" 20 116-2406-904848 US $3,870.00
45° Lateral
Main Line Lateral Line

Maximum

Inflation

Pipeline

Max. Head*

Inflation

Port

Shpg
Wt
lbs
Item
Number
Unit
Price
Each

Maximum

Diameter

Contact

Length

Maximum

Diameter

Contact

Length

in mm in mm in mm in mm psig bar ft m (QC)
4 102 16 406 2 51 16 406 25 1.7 28 8.8 1/4" 6 116-0402-451616 US $1,370.00
6 152 18 457 4 102 24 610 25 1.7 28 8.8 1/4" 8 116-0604-451824 US $1,590.00
8 203 24 610 4 102 32 812 25 1.7 28 8.8 1/4" 10 116-0804-452432 US $2,070.00
10 254 40 1016 4 102 40 1016 25 1.7 28 8.8 1/4" 12 116-1004-454040 US $2,475.00
12 305 48 1219 6 152 48 1219 25 1.7 28 8.8 1/4" 14 116-1206-454848 US $2,910.00
18 457 48 1219 6 152 48 1219 25 1.7 28 8.8 1/4" 18 116-1806-454848 US $3,540.00
24 610 48 1219 6 152 48 1219 25 1.7 28 8.8 1/4" 20 116-2406-454848 US $4,260.00

Advise position of lateral on main line

Nylon loops on each of three ends for positioning

Other sizes & lengths also available

*QC Quick connection.

By-Pass Option - call for prices

*Inflatable Plug Warning: Maximum head pressures that a pipe plug may restrain can only be estimated. Slippage is influenced by many factors including fluid in the pipe, coefficient of pipeline friction, pressure required to inflate the plug, and accuracy of pressure gauges. Generally, a Multi-Flex™ Inflatable Plug inserted fully into pipeline will begin slipping between 50% and 80% of the inflation pressure if it has an inflated pipe contact length of 1 ½ to 2 times the diameter, but even a head of 50% of the inflation pressure may cause slippage with some liquids. The inflation pressure is also subject to temperature change and debris or protrusions in the pipeline that could rupture the plug. The inflation pressure should be monitored and plugs anchored and/or mechanically blocked when slippage may cause property damage or injury.  NEVER use a test pressure greater than the capacity of the weakest pipe or component in the system. NEVER use an inflatable plug when its failure would cause injury.

Price subject to change without notice

Petersen Terms & Conditions Apply

Products covered by one or more of the following patents: 4,565,222; 5,353,842; 5,901,752; 6,446,669; 6,568,429; 6,899,138 and other applications pending.