Address your needs quickly by calling 800-926-1926 or 262-692-2416

129 Series High Pressure Multi-Flex™ High Pressure Line Stop Plugs Sizes: 2" to 96"

 
 

Petersen Inflatable Pipe Plugs Generic Operating Instruction Manual

129-Series Multi-Flex™ Line Stop Plug Hot Tap Installation Instructions

Compact Diameter Allows Insertion Through a Small Hot Tap in a Pressurized Pipeline

Petersen Inflatable Multi-Flex Pipe Plug Insertion System installs a plug into a pressurized pipeline without removing pressure. This allows for maintenance of pipelines without reducing pressure or emptying the pipeline. There are two Petersen Hot Tap Insertion Systems.

The 128 Series Multi-Flex Plug requires a smaller hot tap size and is installed down stream of the hot tap. This allows the plug launching system to also bypass flow upstream of the plug. The 129 Series Plug can be built for much higher pressures than the 128 series but requires a somewhat larger hot tap and inflates immediately below the hot tap. When the project is complete a Completion Valve may be installed and the tapping valve removed.

. Petersen can provide complete hot tap plugging systems and on-site technical support. Email us at sales@petersen.cc or call 1-800-926-1926 for all your pipeline plugging requirements.

Hot Tap Insertion, Flange Inflation, Higher Pressure

End inflation port also available

Hot Tapping Assembly

hot tap plugging



Other pressures, sizes, and
configurations available

 

 

deflated line stop plug

Plug deflated for insertion
through a hot tap

 

Click an Item Number below for the Web Store

Hot Tap Plugs (Other Sizes and Pressures Available)

Plug Diameter
Maximum
**Pipeline

Inflation
Flange

Inflated Seal Length Shpg
Wt
lbs
Item
Number

Unit

Price

Each

Maximum Hot Tap
Inflation
Max. Head
in mm in mm psig bar ft m in mm
2 50 2 50 90 6.2

103

31.3

1/4" mnpt

4 102 2 129-002 US $996.00
3 76 3 76 90 6.2

103

31.3 1/4" mnpt 6 152 3 129-003 US $996.00
4 102 3.5 89 90 6.2

103

31.3 1/2" mnpt 10 254 4 129-004 US $996.00
6 152 4.0 102 90 6.2

103

31.3 1/2" mnpt

10

254 5 129-006 US $1,134.00
8 203 6.0 152 90 6.2

103

31.3 1/2" mnpt 12 305 8 129-008 US $1,254.00
10 254 6.0 152 90 6.2

103

31.3 1/2" mnpt 15 381 11 129-010 US $1,440.00
12 305 8.0 203 90 6.2

103

31.3 1" x 150 lb 18 457 20 129-012 US $1,671.00
15 381 8.0 203 57 4.0 64 19.5 1" x 150 lb 22 558 25 129-015 US $2,172.00
16 406 10.0 254 48 3.3 54 16.5 1 1/4" x 300 lb 24 610 28 129-016 US $2,229.00
18 457 10.0 254 48 3.3 54 16.5 1 1/4" x 300 lb 27 685 33 129-018 US $2,736.00
20 508 10.0 254 40 2.8 45 13.7 1 1/4" x 300 lb 30 762 35 129-020 US $3,600.00
24 610 12.0 305 37 2.6 42 12.8 2" x 300 lb 36 914 37 129-024 US $4,089.00
30 762 12.0 305 30 2.0 34 10.5 2" x 300 lb 45 1143 53 129-030 US $6,741.00
33 838 12.0 305 30 2.0 34 10.5 2" x 300 lb 49 1244 56 129-033 US $7,107.00
36 914 12.0 305 27 1.8 31 9.4 2" x 300 lb 54 1372 70 129-036 US $7,467.00
42 1067 16.0 406 21 1.5 24 7.3 4" x 300 lb 63 1600 83 129-042 US $10,854.00
48 1219 16.0 406 15 1.0 17 5.2 4" x 300 lb 72 1829 109 129-048 US $12,456.00
54 1372 16.0 406 12 0.8 14 4.3 4" x 300 lb 81 2057 144 129-054 US $15,213.00
60 1524 18.0 457 10 0.7 11 3.5 4" x 300 lb 90 2286 148 129-060 US $18,804.00
66 1676 20.0 508 10 0.7 11 3.5 4" x 300 lb 99 2514 165 129-066 US $22,445.00
72 1829 24.0 610 10 0.7 11 3.5 6" x 300 lb 108 2743 180 129-072 US $29,258.00
84 2133 24.0 610 10 0.7 11 3.5 6" x 300 lb 126 3200 210 129-084 US $38,077.00
96 2438 30.0 762 10 0.7 11 3.5 6" x 300 lb 144 3657 240 129-096 US $46,895.00

**Inflatable Plug Warning: Maximum head pressures that a pipe plug may restrain can only be estimated. Slippage is influenced by many factors including fluid in the pipe, coefficient of pipeline friction, pressure required to inflate the plug, and accuracy of pressure gauges. Generally, a Multi-Flex™ Inflatable Plug inserted fully into pipeline will begin slipping between 50% and 80% of the inflation pressure if it has an inflated pipe contact length of 1 ½ to 2 times the diameter, but even a head of 50% of the inflation pressure may cause slippage with some liquids. The inflation pressure is also subject to temperature change and debris or protrusions in the pipeline that could rupture the plug. The inflation pressure should be monitored and plugs anchored and/or mechanically blocked when slippage may cause property damage or injury.  NEVER use a test pressure greater than the capacity of the weakest pipe or component in the system. NEVER use an inflatable plug when its failure would cause injury.

Price subject to change without notice

Petersen Terms & Conditions Apply

Products covered by one or more of the following patents: 4,565,222; 5,353,842; 5,901,752; 6,446,669; 6,568,429; 6,899,138 and other applications pending.